We need to conduct a comprehensive inspection of the industrial electric push rod brake
Jan 10,2022
An important operating component in some devices is the industrial electric push rod brake. Due to its frequent operation, it is also prone to malfunctions. What should we do when the push rod brake fails?
We need to understand the basic structure of the brake, which is mainly composed of industrial electric push rods, pull rods, brake arms, brake shoes, adjusting screws, and bases. So once a malfunction occurs, it is necessary to conduct a comprehensive inspection of these components. This includes checking whether the brake bracket has deformed, whether the hydraulic push rod seal is normal, the gap between the brake pads, and the braking force between them and the brake wheels.
When conducting specific maintenance, first remove the electric hydraulic push rod from the brake, open the oil drain plug, and drain the hydraulic oil completely. Then remove the crossbeam in order, remove the motor, remove the connecting bolts of the cylinder head, and take out the impeller and piston. After disassembly, clean and inspect all components to ensure they are correct before installing them in the same way.
The above mainly focuses on the maintenance of industrial electric push rods, as well as the maintenance of the brake frame of the brake. If any damage is found in any part, it should be repaired in a timely manner. If it cannot be repaired, a new one should be replaced. It is necessary to strengthen the inspection and maintenance of various parts of the equipment in daily life, so as to minimize the occurrence of mechanical failures, which is also beneficial for improving production efficiency.